The Siemens P300 ultrasound system is a compact portable device for a wide variety of clinical settings. The new system comes from the Acuson heritage and integrates high-performance hardware and software and offers 13 different transducers to show it's versatility.
The system also features advanced image optimization
technologies to support both routine and specialty application needs.
The Siemens P300 system is characterized by its comprehensive
capabilities, compact and elegant design. This system might just be the one for you!
The Siemens P300 system (Also known as the Acuson P300.) features a small footprint that makes it easy to store and move around your facility. It has a 15-inch XVGA LCD display and two transducer ports for maximum ease of use and image viewing.
The system enables linear, convex, phased array and endocavity scanning probes to provide solutions for a wide range of clinical cases.
The Siemens P300 ultrasound system is designed to meet the diverse imaging needs for a wide spectrum of patients, body types and clinical disciplines – from radiology and general imaging to cardiovascular imaging, from obstetrics and gynecology (OB/GYN) to specialty imaging including muscoloskeletal, breast and small parts.
It encompasses advanced ultrasound technology and excellent imaging performance in one portable package, thus enabling comprehensive patient care everywhere.
Excellent image quality and workflow efficiency Advanced imaging technologies are standard features in the system mainframe Portable.
An ideal choice for multi-user needs and/or a facility with space constraints.
Backed by experienced clinical application and service support teams.
Standard Options :
TEI,
M View
Color Mode
PW
Color
X View
Vas
Abdomen
Basic Ob
Convex Array Probes:
CA123
• Technology: Wideband Electronic Convex Array
• Depth: 0 – 140 mm
• Footprint: 14 mm radius
• Field of view: 90°
• Operating Bandwidth: 3-9 MHz
• B-M Modes Frequencies: 3 (5.0-6.6-8.0 MHz)
• HHI Frequencies: 2 (Res-Pen)
• C–PW Frequencies: 2 (5.0-6.6 MHz)
• Biopsy: Disposable kit
CA431
• Technology: Wideband Electronic Convex Array
• Number of elements: 192
• Depth: 0 – 360 mm
• Footprint: 40 mm radius
• Field of view: 30°-85°
• Operating Bandwidth: 1-8 MHz
• B-M Modes Freq.s : 4 (2.5-3.5-5.0-6.6 MHz)
• TEI Frequencies: 3 (Gen-Res-Pen)
• C–PW Frequencies: 2 (2.5-2.9 MHz)
• Biopsy: Multi angle reusable autoclave sterilised adaptor
Linear Array Probes
LA522
• Technology: Wideband Electronic Linear Array
• Depth: 0 – 120 mm
• Footprint: 50x8 mm
• Operating Bandwidth: 2-9 MHz
• B-M Modes Frequency: 3 (5-7.5-10 MHz)
• TEI Frequencies: 2 (Pen-Res)
• C–PW Frequencies: 2 (3.3-5) MHz
• Steered angle: 7 steps
• Biopsy: Multi angle reusable autoclave sterilised adaptor
LA435
• Technology: Wideband Electronic Linear Array
• Depth: 0 – 90 mm
• Footprint: 40x5 mm
• Operating Bandwidth: 6-18 MHz
• B-M Modes Frequency: 4 (10-12-15-18 MHz)
• C–PW Frequencies: 2 (6.6-8 MHz)
• Steered angle: 7 steps
• Biopsy: Multi angle reusable autoclave sterilised adaptor
LA523
• Technology: Wideband Electronic Linear Array
• Depth: 0 – 120 mm
• Footprint: 50x8 mm
• Operating Bandwidth: 4-13 MHz
• B-M Modes Frequencies: 3 (7.5-10.0-12.0 MHz)
• HHI Frequencies: 2 (Pen-Res)
• C–PW Frequencies: 2 (5.0-6.6 MHz)
• Steered angle: 7 steps
• Biopsy: Multi angle reusable autoclave sterilised adaptor, disposable kit
Phase Array Probes
PA230
• Technology: Wideband Electronic Phased Array
• Depth: 0-360 mm
• Footprint: 14x23 mm
• Field of view: 15°-90°
• Operating Bandwidth: 1-4 MHz
• B-M Modes Frequencies: 3 (2.0-2.5-3.5 MHz)
• TEI Frequencies: 3 (Pen-Gen-Res)
• C–PW Frequencies: 2 (2.0-2.5 MHz)
• Biopsy: Not Available
PA122
• Technology: Wideband Electronic Phased Array
• Depth: 0 – 270 mm
• Foot print: 10 x 16 mm
• Field of view: 90°
• Operating Bandwidth: 3-8 MHz
• B-M Modes Frequency: 2 (5-7.5 MHz)
• C–PW Frequencies: 3.3 – 5 MHz
• Biopsy: Not Available
PA023
• Technology: Wideband Electronic Phased Array
• Depth: 0 – 270 mm
• Foot print: 6 x 13 mm
• Field of view: 90°
• Operating Bandwidth: 4-11 MHz
• B-M Modes Frequencies: 2 (7.5-10 MHz)
• C–PW Frequencies: 5 MHz
• Biopsy: Not Available
Special Probes
EC1123
•Technology: Wideband Electronic end fire microConvex
• Depth: 0 – 170 mm
• Footprint: 10mm radius
• Field of view: 195°
• Operating Bandwidth: 3-9 MHz
• B-M Modes Frequencies: 4 (4-5-6.6-8 MHz)
• HHI Frequencies: 1 (Res)
• C–PW Frequencies: 5, 6.6 MHz
• Biopsy: Single use adaptor
IOE323
• Application: Intraoperative
• Technology: Wideband Electronic Linear Array
• Depth: 0 – 90 mm
• Footprint: 30mm
• Operating Bandwidth: 4-13 MHz
• B-M Modes Frequencies: 3 (5.0-7.5-12 MHz)
• C–PW Frequencies: 2 (5-6.6 MHz)
• Biopsy: Multi angle reusable autoclave sterilised adaptor
LP323
• Application: Laparoscopic
• Technology: Wideband Electronic Linear Array
• Depth: 0 – 90 mm
• Operating Bandwidth: 4-13 MHz
• B-M Modes Frequencies: 3 (5.0-7.5-12 MHz)
• C–PW Frequencies: (5-6.6 MHz)
• Articulation ± up/down 90°
• Articulation ± right/left 90°
• Biopsy: Not Available
Non – Imaging Pencil probe
2MHz CW - Doppler
• Number of elements: 2
• Doppler Frequencies: 2 MHz
5MHz PW - Doppler
• Number of elements: 2
• Doppler Frequencies: 5 MHz
If you have any questions please send them into us using the form below.